Cleanroom Ventilation System_ HVAC

At Chempharm India, we provide advanced HVAC systems designed to maintain critical temperature, humidity, and air quality in controlled environments. Our solutions cater to industries including pharmaceuticals, food and beverages, and electronics, where precise environmental control is essential. We focus on energy-efficient designs, seamless integration, and compliance with industry standards, ensuring optimal performance and safety for cleanrooms and sensitive operational spaces.

What is HVAC?

HVAC usually refers to the mechanical system that provides heating, ventilation and/or cooling within a residential or commercial building or a premise. An HVAC system is designed to control the environment in which it functions. HVAC system does this by controlling the air cleanliness of the air in that environment.

Technical Requirements and Relevant Standards

Ventilation in this process helps in replacing the air within the space and ensures a better quality of air indoors. The HVAC system helps in providing good quality air by removing all the moisture, heat, dust, bacteria (airborne), CO2, among some other gases.

Air Handling Units

 with forward and backward fans duly tested

Motors and Electrical

 Suitable Motors for AHU Handling

Insulation

 Ducting / Pipes using Neoprene or APO

BMS System

High-end in-built BMS system to improve the overall energy efficiency, controls, monitoring, performance.

Quality Check

All equipment are validated and shipped prior to dispatch with DQ,IQ,PQ,OQ as per GMP STD

Chillers

Water Cooled or Air Cooled as per requirements

Types of HVAC Systems?

The most common types of HVAC systems are as follows:

Heat Pump – Heat pumps sucks in heat from a cold space or environment and warms it to release in the room to maintain the temperature

Rooftop Unit – Rooftop HVAC systems are usually preferred to manage the temperature of a large space. It is a large unit which is placed on the rooftop of the building

Water Source Heat Pump – This type of HVAC system is uncommon in today’s time as geothermal HVAC systems are picking up the trend nowadays. The water source heat pump is exactly what the name suggests as they require proximity to a body of water to work

Packaged HVAC – Packaged HVAC systems are similar to the rooftop HVAC systems but are preferred for smaller areas/rooms or domestic use.

Split System HVAC – Split system HVAC means that there are 2 units of the system – outdoor and indoor. There are two types of split system HVAC – ductless and central)

Ductless HVAC – These HVAC systems are the most preferred HVAC systems for a single large room or multiple small rooms.

Trusted Excellence

What Sets Us Apart from Competitors

Chempharm India offers Cleanroom HVAC systems with total facility solution as per EU GMP/PICs (Pharmaceutical inspection Convention/U.S. FDA/W.H.O. Compliance. Chempharm India provides tailor made HVAC system, which are designed taking into consideration the demanding requirements of Relative Humidity, Temperature, Positive or Negative Pressurization, Airborne Particle Classification, Air Flow Patterns and much more.

Unrivaled Expertise

Chempharm has expertise to offer you HVAC systems for hygroscopic powder based pharmaceutical products with very low RH in the range of 25-40% based on product requirement. Most of the oral solid dosses products need 55% RH +/- 5% which can be controlled using Condensing load and some heaters.  LOW RH can be achieved using AHU with inbuilt De humidifiers or dehumidifiers as separate.

Personalized Solutions

We serve turnkey solutions for HVAC and Cleanrooms considering standards for Designing, commission and validation which are tailored to meet your specific needs, while being compliant with regulatory standards. You can buy HVAC system as per your requirement from Chempharm India to ensure the cleanroom architecture.

Timely Delivery

We value your time and guarantee prompt delivery of our products/services. HVAC Systems for cleanroom for Pharmaceutical, Electronic and Food and beverages Industries etc. can be sourced from Chempharm with Full technical back up and designs.

Which is the Best HVAC System available?

Chempharm India provides the best HVAC system available in the market. You can ASK CHEMPHARM EXPERTS to design a most customized HVAC system as per your requirement and budget. To ensure best quality, Chempharm India incorporates the following key elements: (HVAC SYSTEM FOR CLEAN ROOM)

Clean Room HVAC System – The integrity of the cleanroom environment is created by the pressure differential compared with adjacent areas through air flow pattern.

The HVAC system requirements include:

Supplying airflow in sufficient volume and cleanliness to support the cleanliness rating of the room

Introducing air in a manner to prevent stagnant areas where particles could accumulate

Filtering the outside and re-circulated air across high efficiency particulate air (HEPA) filters

Conditioning the air to meet the cleanroom temperature and humidity requirements

Ensuring enough conditioned makeup air to maintain the specified positive pressurization

Monitoring systems – Monitoring systems include a means of indicating that the cleanroom is functioning properly. The variables monitored are the pressure differential between the outside environment and the cleanroom, temperature, humidity and, in some cases, noise and vibrations. Control data should be recorded on a routine basis.

HVAC System Design for Clean Facility– HVAC systems in cleanrooms are substantially different from their counterparts in commercial buildings in terms of equipment design, system requirements, reliability, size and scale.

Cleanroom HVAC Vs Air Conditioned Space

Increased Air Supply: Whereas comfort air conditioning would require about 2-10 air changes/hr, a typical cleanroom would typically require 30 – 80 air changes and could be as high as 600 for absolute cleanliness.

The use of high efficiency filters: The use of high efficiency particulate air (HEPA) filters having filtration efficiency of 99.9997% down to 0.3 microns is another distinguishing feature of cleanrooms. The HEPA filters for stringent cleanrooms are normally located at the terminal end and in most cases provide 100% ceiling coverage.

De-humidifiers  in few cases would be needed to control RH in the HVAC systems for hygroscopic pharma products or specialized electronic sectors .

Room pressurization: The cleanroom is positively pressurized (to 0.05 in-wc) with respect to the adjacent areas. This is done by supplying more air and extracting less air from the room than is supplied to it.

Frequently Asked Questions